diff options
author | Pacho Ramos <pacho@gentoo.org> | 2013-09-28 10:13:46 +0000 |
---|---|---|
committer | Pacho Ramos <pacho@gentoo.org> | 2013-09-28 10:13:46 +0000 |
commit | 734741337fb9a5b485f8f69ceeecdbdd4c5ab2f1 (patch) | |
tree | f7b165751dec3b98d7c7cc6a6058d1682ceb2342 /sys-power | |
parent | Backport unit files to allow faster stabilization (diff) | |
download | historical-734741337fb9a5b485f8f69ceeecdbdd4c5ab2f1.tar.gz historical-734741337fb9a5b485f8f69ceeecdbdd4c5ab2f1.tar.bz2 historical-734741337fb9a5b485f8f69ceeecdbdd4c5ab2f1.zip |
Backport unit files to allow faster stabilization
Package-Manager: portage-2.2.7/cvs/Linux x86_64
Manifest-Sign-Key: 0xA188FBD4
Diffstat (limited to 'sys-power')
-rw-r--r-- | sys-power/apcupsd/ChangeLog | 7 | ||||
-rw-r--r-- | sys-power/apcupsd/Manifest | 9 | ||||
-rw-r--r-- | sys-power/apcupsd/apcupsd-3.14.8-r2.ebuild | 130 |
3 files changed, 141 insertions, 5 deletions
diff --git a/sys-power/apcupsd/ChangeLog b/sys-power/apcupsd/ChangeLog index be01850af50f..c4ad1fd49fc2 100644 --- a/sys-power/apcupsd/ChangeLog +++ b/sys-power/apcupsd/ChangeLog @@ -1,6 +1,11 @@ # ChangeLog for sys-power/apcupsd # Copyright 1999-2013 Gentoo Foundation; Distributed under the GPL v2 -# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/ChangeLog,v 1.83 2013/08/31 12:46:20 pacho Exp $ +# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/ChangeLog,v 1.84 2013/09/28 10:13:42 pacho Exp $ + +*apcupsd-3.14.8-r2 (28 Sep 2013) + + 28 Sep 2013; Pacho Ramos <pacho@gentoo.org> +apcupsd-3.14.8-r2.ebuild: + Backport unit files to allow faster stabilization *apcupsd-3.14.10-r2 (31 Aug 2013) diff --git a/sys-power/apcupsd/Manifest b/sys-power/apcupsd/Manifest index 89c92dd3f2c8..0c36d507314a 100644 --- a/sys-power/apcupsd/Manifest +++ b/sys-power/apcupsd/Manifest @@ -13,12 +13,13 @@ DIST apcupsd-3.14.8.tar.gz 1317601 SHA256 8e7f2574d3abaf6637da3e790860c3f9ba64fa EBUILD apcupsd-3.14.10-r1.ebuild 4060 SHA256 8bd603ca14f6e42a573559d8588354240f74a4eff4b4cab7d62f460320e06fd8 SHA512 6b37efe12be278bce4b6bf7a17c88641bfe13c8304c383112a3309fca33609ca9d02ede3b6c23ed325064878da6e4c8f441ad39e92e68d791fd6348c228f0ca3 WHIRLPOOL 470e178eff2d7e1dcdc19e1860396dd9ca494f10d6e15ab60a9635b763b0f60192a883bec5a5c60ccc00fc3f48aa0035117804384d03d17b8e1cc23be949d579 EBUILD apcupsd-3.14.10-r2.ebuild 4177 SHA256 3ee47fde9a2f7be55208b2f2bbe88fe1cdf57c21783486195e7a904d476bf680 SHA512 af68e532b23719323a88e61e222eb48b5502d022d6d1ea21d56352edbe5cfeeb844b483d77c451940b6eb01c713bcc206b4365369bda7082794cdc327b2e3d0e WHIRLPOOL 54c92f7dffea8841af85867173c36cd361732a0e4ef90f3020c5e2ed7a8078eb2e1157441c2510b234cb7fdb04ee4b36b29dfb296d9227ebe8aa1bc968015599 EBUILD apcupsd-3.14.8-r1.ebuild 3863 SHA256 f5d984daecd4a0af67bdd5c44abeea7a4f47ed6ee94623e64e89116ff77e83b5 SHA512 5abc26eb6a258f39d7b4a617e87ee00a51c23aaeff76edd9fbc5a7b898552c5e1a270acd941d7e4d5818184d807e986da0593c239f6945c8d652867966197220 WHIRLPOOL 6ef00f538fdd0da2ac2639ece9e3209ba87190032c650cb003e7358e9f8e66f5255f58bacd0a59a7a16f17f2c393af4fb23eba14af403289444fc18d5b0140d4 -MISC ChangeLog 26842 SHA256 194461f90ade0728c0bd2bc77685f4d8c19b009f8a5fa14aecbbefa5e7af3431 SHA512 d607d09cb31e6b593beb082f18e929c663d06c899527a23e2693d763b83dad89733cda7d075a31e3e39c3f1a505640423936f542dd969b4a5def494b74ea0229 WHIRLPOOL efc3489780f3ce8a37a2275668f2899ce0c3bc3f6bb2633e6c0ab337a23905b0c6c00a7fb01f357bf310806cd947fbfb0d489ffeddb579cf38f204157c752032 +EBUILD apcupsd-3.14.8-r2.ebuild 3972 SHA256 07518df91623ac0c1ce6de2f1cc5e152d890b0ac31b6ee20349b887d6456a272 SHA512 25b703ac0626173e8b8b933b6142d594acd24939fa08df58483c62b084dd57230240ccecb853e48b1491bced1cae8e78f8b1024c2842484fe642eb47712201f4 WHIRLPOOL 899c9f698a8be7b42f21b627e0828e71d8a3a0c33c297d4189b485e51e3bb2b923a11ef929acb932d029989576056543f546f4a2e8efddb6af1157879c200795 +MISC ChangeLog 27002 SHA256 b110393c806f42452a7724b37055e328ea37b4924294aceebb7ce4bef8794f25 SHA512 91efedfe711f50fc75a24c6bd0a39ebcabdfed2726c4b1841a5512f1ba35ec249df661e8cd6648b520b7ce9e1de1160332dea18347ffacbd964169989fab1c17 WHIRLPOOL 699c5e8c6feb91effd6226f7d716e6f228dc10b8641692a0112dad548696f1051f8d2f4c4cd0389eca8ca8ae6e846c646f4c2ed19dc06873938b5ac1f64379d8 MISC metadata.xml 854 SHA256 ed821e0f70dad05d8ec1475d40654bb39a4d4ce0e9afb3901282dd05a3662cc5 SHA512 b3d9dbbb217711502dc36e1aca3c6efb18eb31a1f375241ed12a5e1312e19fd74e3659bb9bab3afd9eeff41de7f643a367a406bab09a1bce9d7f41b5e28da988 WHIRLPOOL 7ed63a7e8f4560fccc24d664e6d43c0a9b726b7c41cb1504753869633611968d3d4d29403b07dd0c17e40c8e368b01450d36cf44215906843ff70d505bd0fb7c -----BEGIN PGP SIGNATURE----- Version: GnuPG v2.0.20 (GNU/Linux) -iEYEAREIAAYFAlIh5Z4ACgkQCaWpQKGI+9R2swCeMPNEE2kL1+l5si5GBKc7arCM -NbIAn0a0367jQI6EPMzd3c5y5H9B7LcN -=tH83 +iEYEAREIAAYFAlJGq9cACgkQCaWpQKGI+9TxMACdHiJD5PN+ryt4HZ1+QpTdQZ9w +si0An0oltHxU9ks4Z67p5Wu3abNhO5sl +=HrQs -----END PGP SIGNATURE----- diff --git a/sys-power/apcupsd/apcupsd-3.14.8-r2.ebuild b/sys-power/apcupsd/apcupsd-3.14.8-r2.ebuild new file mode 100644 index 000000000000..2a4897450bdc --- /dev/null +++ b/sys-power/apcupsd/apcupsd-3.14.8-r2.ebuild @@ -0,0 +1,130 @@ +# Copyright 1999-2013 Gentoo Foundation +# Distributed under the terms of the GNU General Public License v2 +# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/apcupsd-3.14.8-r2.ebuild,v 1.1 2013/09/28 10:13:42 pacho Exp $ + +EAPI=3 + +inherit eutils linux-info flag-o-matic systemd + +DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown" +HOMEPAGE="http://www.apcupsd.org/" +SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz" + +LICENSE="GPL-2" +SLOT="0" +KEYWORDS="~amd64 ~ppc ~x86 ~x86-fbsd" +IUSE="snmp +usb cgi nls gnome kernel_linux" + +DEPEND=" + cgi? ( >=media-libs/gd-1.8.4 ) + nls? ( sys-devel/gettext ) + snmp? ( net-analyzer/net-snmp ) + gnome? ( >=x11-libs/gtk+-2.4.0:2 + dev-libs/glib:2 + >=gnome-base/gconf-2.0 )" +RDEPEND="${DEPEND} + virtual/mailx" + +CONFIG_CHECK="~USB_HIDDEV ~HIDRAW" +ERROR_USB_HIDDEV="CONFIG_USB_HIDDEV: needed to access USB-attached UPSes" +ERROR_HIDRAW="CONFIG_HIDRAW: needed to access USB-attached UPSes" + +pkg_setup() { + if use kernel_linux && use usb && linux_config_exists; then + check_extra_config + fi +} + +src_configure() { + local myconf + use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=/usr/libexec/${PN}/cgi-bin" + if use usb; then + myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= " + else + myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb" + fi + + append-flags -fno-strict-aliasing + + # We force the DISTNAME to gentoo so it will use gentoo's layout also + # when installed on non-linux systems. + econf \ + --sbindir=/sbin \ + --sysconfdir=/etc/apcupsd \ + --with-pwrfail-dir=/etc/apcupsd \ + --with-lock-dir=/var/lock \ + --with-pid-dir=/var/run \ + --with-log-dir=/var/log \ + --with-nis-port=3551 \ + --enable-net --enable-pcnet \ + --with-distname=gentoo \ + $(use_enable snmp net-snmp) \ + $(use_enable gnome gapcmon) \ + ${myconf} \ + APCUPSD_MAIL=/bin/mail \ + || die "econf failed" +} + +src_compile() { + # Workaround for bug #280674; upstream should really just provide + # the text files in the distribution, but I wouldn't count on them + # doing that anytime soon. + MANPAGER=$(type -p cat) \ + emake || die "emake failed" +} + +src_install() { + emake DESTDIR="${D}" install || die "installed failed" + rm -f "${D}"/etc/init.d/halt + + insinto /etc/apcupsd + newins examples/safe.apccontrol safe.apccontrol + + dodoc ChangeLog* ReleaseNotes + doman doc/*.8 doc/*.5 || die "doman failed" + + dohtml -r doc/manual/* || die "dodoc failed" + + rm "${D}"/etc/init.d/apcupsd + newinitd "${FILESDIR}/${PN}.init.2a" "${PN}" || die "newinitd failed" + systemd_dounit "${FILESDIR}"/${PN}.service + systemd_dotmpfilesd "${FILESDIR}"/${PN}-tmpfiles.conf + + if has_version sys-apps/openrc; then + newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail || die "newinitd failed" + fi + + # remove hal settings, we don't really want to have it around still. + rm -r "${D}"/usr/share/hal + + # Without this it'll crash at startup. When merging in ROOT= this + # won't be created by default, so we want to make sure we got it! + keepdir /var/lock + fowners root:uucp /var/lock + fperms 0775 /var/lock +} + +pkg_postinst() { + if use cgi; then + elog "The cgi-bin directory for ${PN} is /usr/libexec/${PN}/cgi-bin." + elog "Set up your ScriptAlias or symbolic links accordingly." + fi + + elog "" + elog "Since version 3.14.0 you can use multiple apcupsd instances to" + elog "control more than one UPS in a single box." + elog "To do this, create a link between /etc/init.d/apcupsd to a new" + elog "/etc/init.d/apcupsd.something, and it will then load the" + elog "configuration file at /etc/apcupsd/something.conf." + elog "" + + if [ -d "${ROOT}"/etc/runlevels/shutdown -a \ + ! -e "${ROOT}"/etc/runlevels/shutdown/"${PN}".powerfail ] ; then + elog 'If you want apcupsd to power off your UPS when it' + elog 'shuts down your system in a power failure, you must' + elog 'add apcupsd.powerfail to your shutdown runlevel:' + elog '' + elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m' + elog '' + fi +} |