blob: 55e0dadd7602d7e2bb3c9b783af3b89507af9027 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
|
# Copyright 1999-2009 Gentoo Foundation
# Distributed under the terms of the GNU General Public License v2
# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/apcupsd-3.14.5-r2.ebuild,v 1.3 2009/05/22 12:50:13 fauli Exp $
WEBAPP_MANUAL_SLOT="yes"
WEBAPP_OPTIONAL="yes"
inherit eutils webapp
DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown"
HOMEPAGE="http://www.apcupsd.org/"
SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz"
LICENSE="GPL-2"
SLOT="0"
KEYWORDS="~alpha ~amd64 ppc ~sparc x86 ~x86-fbsd"
IUSE="doc snmp usb cgi nls gnome"
DEPEND="doc? ( virtual/latex-base
dev-tex/latex2html
app-text/dvipdfm )
cgi? ( >=media-libs/gd-1.8.4
${WEBAPP_DEPEND} )
nls? ( sys-devel/gettext )
snmp? ( net-analyzer/net-snmp )
gnome? ( >=x11-libs/gtk+-2.4.0
>=dev-libs/glib-2.0
>=gnome-base/gconf-2.0 )"
RDEPEND="${DEPEND}
virtual/mailx"
pkg_setup() {
use cgi && webapp_pkg_setup
}
src_compile() {
local myconf
use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=${MY_CGIBINDIR}"
if use usb; then
myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= "
else
myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb"
fi
# We force the DISTNAME to gentoo so it will use gentoo's layout also
# when installed on non-linux systems.
econf \
--sbindir=/sbin \
--sysconfdir=/etc/apcupsd \
--with-pwrfail-dir=/etc/apcupsd \
--with-lock-dir=/var/lock \
--with-pid-dir=/var/run \
--with-log-dir=/var/log \
--with-nis-port=3551 \
--enable-net --enable-pcnet \
--with-distname=gentoo \
$(use_enable snmp net-snmp) \
$(use_enable gnome gapcmon) \
${myconf} \
APCUPSD_MAIL=/bin/mail \
|| die "econf failed"
emake || die "emake failed"
if use doc; then
einfo "Building full documentation..."
cd "${S}"/doc/latex
emake -j1 texcheck tex web pdf || die "doc build failed"
fi
}
src_install() {
use cgi && webapp_src_preinst
emake DESTDIR="${D}" install || die "installed failed"
rm -f "${D}"/etc/init.d/halt
insinto /etc/apcupsd
newins examples/safe.apccontrol safe.apccontrol
dodoc ChangeLog* ReleaseNotes
newman doc/apctest.man apctest.8 || die "newman failed"
if use doc; then
einfo "Installing full documentation..."
newdoc doc/latex/apcupsd.pdf manual.pdf || die "pdf doc failed"
dohtml -r doc/latex/apcupsd/* || die "doc install failed"
fi
use cgi && webapp_src_install
rm "${D}"/etc/init.d/apcupsd
newinitd "${FILESDIR}/${PN}.init.2" "${PN}" || die "newinitd failed"
newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail || die "newinitd failed"
}
pkg_postinst() {
if use cgi; then
elog "If you are upgrading from a previous version, please note"
elog "that the CGI interface is now installed using webapp-config."
elog "/var/www/apcupsd is no longer present."
webapp_pkg_postinst
fi
elog ""
elog "Since version 3.14.0 you can use multiple apcupsd instances to"
elog "control more than one UPS in a single box."
elog "To do this, create a link between /etc/init.d/apcupsd to a new"
elog "/etc/init.d/apcupsd.something, and it will then load the"
elog "configuration file at /etc/apcupsd/something.conf."
elog ""
if [ -d "${ROOT}"/etc/runlevels/shutdown -a \
! -e "${ROOT}"/etc/runlevels/shutdown/"${PN}".powerfail ] ; then
elog 'If you want apcupsd to power off your UPS when it'
elog 'shuts down your system in a power failure, you must'
elog 'add apcupsd.powerfail to your shutdown runlevel:'
elog ''
elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m'
elog ''
fi
}
pkg_prerm() {
use cgi && webapp_pkg_prerm
}
|